Properties of Nyquist Systems

From LNTwww


First Nyquist criterion in the time domain


For the entire first main chapter it was assumed that the detection of a symbol should not be affected by neighboring pulses.  This is achieved by the detection of the signal

$$d(t) = d_{\rm S}(t) = \sum \limits_{\it (\nu)} a_\nu \cdot g_d ( t - \nu T)$$

at the detection times  $(\nu \cdot T)$  whenever the basic detection pulse  $g_d(t)$


For the sake of simplicity,  the noise component of the detection signal is assumed to be negligibly small in the following   ⇒   $d_{\rm N}(t) =0$.

$\text{Definition:}$  One denotes a basic detection pulse with the properties

$$g_d ( t = \nu T)= 0 \hspace{0.3cm}{\rm{for} }\hspace{0.3cm} \nu = \pm 1, \pm 2,\pm 3,\hspace{0.05cm}\text{...}$$

as  Nyquist pulse  $g_{\hspace{0.05cm}\rm Nyq}(t)$,  named after the physicist  "Harry Nyquist".


Detection signal with Nyquist pulse shaping

$\text{Example 1:}$  The diagram shows the detection signal  $d(t)$  of such a Nyquist system.  Dotted in red are the  (weighted and shifted)  Nyquist pulses  $a_\nu \cdot g_{\hspace{0.05cm}\rm Nyq}(t -\nu \cdot T)$. 

Please note:

  • At the detection times hold   $d(\nu \cdot T) = a_\nu \cdot g_{\hspace{0.05cm}\rm Nyq}(0)$,  as shown by the blue circles and the green grid.
  • The trailing edge   ⇒   "trailers"  of preceding pulses  $(\nu < 0)$  as well as the rising edge   ⇒   "precursors"  of following pulses  $(\nu > 0)$  do not affect the detection of the symbol  $a_0$  in the Nyquist system.


It should be mentioned that this graph is valid for the basic detection pulse with trapezoidal spectrum and rolloff factor  $r = 0.5$:

$$g_{\hspace{0.05cm}\rm Nyq} ( t )= g_0 \cdot {\rm sinc} \left ( \frac{t}{T}\right)\cdot {\rm sinc} \left ( \frac{ t}{2 \cdot T}\right),$$

which has already been discussed in the section  "Trapezoidal low-pass filter"  of the book  "Linear Time Invariant Systems".


First Nyquist criterion in the frequency domain


"Harry Nyquist"  formulated the condition for detection without intersymbol interfering not only for the time domain,  but in 1928 he also gave the corresponding criterion in the frequency domain.

$\text{First Nyquist criterion:}$  If the spectrum  $G_d(f)$  of the basic detection pulse  $g_d(t)$  fulfills the condition

$$\sum \limits_{\it k = -\infty}^{+\infty} G_d \left ( f - {k}/{T} \right)= g_0 \cdot T = {\rm const.} \hspace{0.05cm}, $$

then  $g_d(t)$  is a Nyquist pulse

  • with equidistant zero crossings at the times  $\nu \cdot T$  for  $\nu \ne 0$  and
  • the amplitude  $g_d(t = 0) = g_0$.


$\text{Note}$:  The proof follows in the  "next section".


$\text{Example 2:}$  Sketched are two Nyquist spectra  $G_1(f)$  and  $G_2(f)$, which are composed of rectangular and triangular segments:

The purely real spectrum sketched  $G_1(f)$  on the left satisfies the condition formulated above with the smallest possible bandwidth:

Illustration of the first Nyquist criterion
$$G_1(f) \hspace{-0.05cm}=\hspace{-0.05cm} \left\{ \begin{array}{c} g_0 \cdot T \\ 0 \\ \end{array} \right. \begin{array}{*{1}c} \text{for} \\ \text{for} \\ \end{array}\begin{array}{*{20}c} \vert f \vert \hspace{-0.08cm}<\hspace{-0.08cm} {1}/(2T), \\ \vert f \vert \hspace{-0.08cm}>\hspace{-0.08cm} {1}/(2T), \\ \end{array}$$

But the associated Nyquist pulse  $g_1(t) = g_0 \cdot {\rm sinc}(t/T)$  decays very slowly, asymptotically with  $1/t$.


The real part of the spectrum  $G_2(f)$  shown on the upper right was constructed from the rectangular spectrum by $G_1(f)$  by shifting parts of them by  $1/T$  to the right or to the left. 

  • $G_2(f)$  is also a Nyquist spectrum because of
$$\sum \limits_{\it k = -\infty}^{+\infty} {\rm Re}\big[G_2 \left ( f - {k}/{T} \right)\big]= g_0 \cdot T \hspace{0.05cm},$$
$$\sum \limits_{\it k = -\infty}^{+\infty} {\rm Im}\left[G_2 \big ( f - {k}/{T} \right)\big]= 0.$$
  • In the imaginary part,  the respective equally shaded parts,  each  $2/T$  apart,  cancels out.
  • However,  the specification of the corresponding Nyquist pulse  $g_2(t)$  is very complicated.


Proof of the first Nyquist criterion


(1)   We start from the first Nyquist condition in the time domain:

$$g_{\hspace{0.05cm}\rm Nyq}(\nu T) = \left\{ \begin{array}{c} g_0 \\ 0 \\ \end{array} \right.\quad \begin{array}{*{1}c} {\rm{for} } \\ {\rm{for} } \\ \end{array}\begin{array}{*{20}c} \nu = 0 \hspace{0.05cm}, \\ \nu \ne 0 \hspace{0.1cm}. \\ \end{array}$$

(2)   Thus,  from the second Fourier integral,  we obtain for  $\nu \ne 0$:

$$g_{\hspace{0.05cm}\rm Nyq}(\nu T) = \int_{-\infty}^{+\infty}G_{\rm Nyq}(f) \cdot {\rm e}^{ \hspace{0.05cm}{\rm j} \hspace{0.05cm}2 \pi f \hspace{0.05cm}\nu \hspace{0.05cm}T}\,{\rm d} f = 0 \hspace{0.05cm}.$$

(3)   Decomposing the Fourier integral into partial integrals of width  $1/T$,  the conditional equations are:

$$\sum_{k = -\infty}^{+\infty} \hspace{0.2cm} \int_{(k-1/2)/T}^{(k+1/2)/T}G_{\rm Nyq}(f) \cdot {\rm e}^{ \hspace{0.05cm}{\rm j} \hspace{0.05cm}2 \pi f \hspace{0.05cm}\nu \hspace{0.05cm}T}\,{\rm d} f = 0 \hspace{0.05cm}.$$

(4)   With the substitution  $f\hspace{0.08cm}' = f + k/T$  it follows:

$$\sum_{k = -\infty}^{+\infty} \hspace{0.2cm} \int_{-1/(2T)}^{1/(2T)}G_{\rm Nyq}(f\hspace{0.08cm}' - \frac{k}{T} ) \cdot {\rm e}^{\hspace{0.05cm}{\rm j} \hspace{0.05cm}2 \pi \hspace{0.05cm} \cdot \hspace{0.05cm} (f\hspace{0.08cm}'- k/T) \hspace{0.05cm} \cdot \hspace{0.05cm}\nu \hspace{0.05cm}T}\,{\rm d} f \hspace{0.08cm}' = 0 \hspace{0.05cm}.$$

(5)   For all integer values of  $k$  and  $\nu$  holds:

$${\rm e}^{ - {\rm j} \hspace{0.05cm}2 \pi \hspace{0.05cm} k \hspace{0.05cm} \nu } = 1 \hspace{0.4cm} \Rightarrow \hspace{0.4cm}\sum_{k = - \infty}^{+\infty} \hspace{0.2cm} \int_{- 1/(2T)}^{1/(2T)}G_{\rm Nyq}(f\hspace{0.08cm}' - \frac{k}{T} ) \cdot {\rm e}^{ {\rm j} \hspace{0.05cm}2 \pi \hspace{0.02cm}f\hspace{0.08cm}' \hspace{0.02cm} \nu \hspace{0.05cm}T}\,{\rm d} f \hspace{0.08cm}' = 0 \hspace{0.05cm}.$$

(6)   Swapping summation and integration and renaming  $f\hspace{0.08cm}'$  to  $f$,  it further follows:

$$\int_{-1/(2T)}^{1/(2T)}\hspace{0.2cm} \sum_{k = - \infty}^{+\infty} G_{\rm Nyq}(f - \frac{k}{T} ) \cdot {\rm e}^{ {\rm j} \hspace{0.05cm}2 \pi \hspace{0.02cm}f \hspace{0.02cm} \nu \hspace{0.05cm}T}\,{\rm d} f = 0 \hspace{0.05cm}.$$

(7)   This requirement can be satisfied for all  $\nu \ne 0$  only if the infinite sum is independent of  $f$,  i.e.,  has a constant value:

$$\sum_{k = -\infty}^{+\infty} G_{\rm Nyq}(f - \frac{k}{T} ) = K_{\rm Nyq} \hspace{0.05cm}.$$

(8)   From the penultimate equation,  we obtain simultaneously for  $\nu = 0$:

$$\int_{-1/(2T)}^{1/(2T)}\hspace{0.2cm} \sum_{k = -\infty}^{+\infty} G_{\rm Nyq}(f - \frac{k}{T} ) \,{\rm d} f = K_{\rm Nyq} \cdot \frac{1}{T} = g_0 \hspace{0.3cm}\Rightarrow \hspace{0.3cm}K_{\rm Nyq} = g_0 \cdot T \hspace{0.05cm}.$$
q.e.d.


1/T Nyquist spectra


Nyquist spectra which are limited to the frequency range  $-1/T \le f \le +1/T$  and are coherent,  have a particular importance for digital signal transmission.

The diagram shows the  "trapezoidal characteristic"  and the  "cosine rolloff characteristic",  which are two variants in this respect. The same applies to both Nyquist spectra:

  • The rolloff occurs between the two corner frequencies  $f_1$  and  $f_2$  point-symmetrically about the  Nyquist frequency  $f_{\rm Nyq} = (f_1+f_2)/2$. 
    That is,  for  $0 \le f \le f_{\rm Nyq}$: 
$$G_{\rm Nyq}(f_{\rm Nyq}+f) + G_{\rm Nyq}(f_{\rm Nyq}-f) = g_0 \cdot T \hspace{0.05cm}.$$
  • For all frequencies  $|f| \le f_1$,  the function  $G_{\rm Nyq}(f)$  is constantly equal to  $g_0 \cdot T$  and for  $|f| \ge f_2$  it is identically zero.
$1/T$  Nyquist spectra
  • In the range between  $f_1$  and  $f_2$  holds:
$$\frac{G_{\rm Nyq}(f)}{g_0 \cdot T } = \left\{ \begin{array}{c} \frac{f_2 - |f|}{f_2 -f_1 } \\ \\ \cos^2( \frac{\pi}{2}\cdot \frac{f_2 - |f|}{f_2 -f_1 }) \\ \end{array} \right.\quad \begin{array}{*{1}c} {\rm{at \hspace{0.15cm}trapezoidal}\hspace{0.05cm},} \\ \\ {\rm{\rm{at \hspace{0.15cm}cosine \hspace{0.15cm}rolloff}}\hspace{0.05cm}.} \\ \end{array}$$
  • To parameterize the slope,  we use the  rolloff factor  $r$,  which can take values between  $0$  and  $1$  (including these limits):
$$r = \frac{f_2 -f_1 } {f_2 +f_1 } \hspace{0.05cm}.$$
In the literature,  the rolloff factor is sometimes referred to as  $\alpha$  ("alpha").
  • For  $r = 0$   ⇒   $f_1 = f_2 = f_{\rm Nyq}$  we obtain in both cases the  (green–dotted)  rectangular Nyquist spectrum.
  • The rolloff factor  $r = 1$   ⇒   $f_1 = 0, \ f_2 = 2 f_{\rm Nyq}$  stands
  1. for the triangular spectrum
  2. resp.  the cosine-square spectrum, 
depending on which of the two basic structures shown above one assumes.  These frequency curves are shown in red dashed lines.



Time domain description of the 1/T Nyquist spectra


Let us now consider the Nyquist pulses.  For the  trapezoidal spectrum  with rolloff factor  $r$,  we obtain:

$$g_{_{\rm trapezoid}} ( t )= g_0 \cdot {\rm sinc} \left ( \frac{t}{T}\right)\cdot {\rm sinc} \left ( \frac{r \cdot t}{T}\right) \hspace{0.5cm}{\rm with }\hspace{0.5cm}{\rm sinc}(x) = {\rm sin}(\pi x)/(\pi x) .$$

In contrast,  the Fourier inverse transform of the  cosine rolloff spectrum  (short:  "CRO spectrum") yields:

$$g_{_{\rm CRO}} ( t )= g_0 \cdot {\rm sinc} \left ( \frac{ t}{T}\right)\cdot \frac{\cos(\pi \cdot r \cdot t/T)}{1 - (2 \cdot r \cdot t/T)^2 } \hspace{0.3cm}{\rm with }\hspace{0.3cm}{\rm sinc}(x) = {\rm sin}(\pi x)/(\pi x).$$

These pulses can be viewed using the HTML5/JS applet  "Frequency & Impulse Responses"  $($with setting  $ \Delta \cdot f = 1)$,  illustrating the influence of the rolloff factor  $r$. 

The following upper diagram shows the Nyquist pulse with trapezoidal spectrum for different rolloff factors. Below is the corresponding time course for the cosine rolloff spectrum. One can see:

Nyquist pulses with trapezoidal and cosine rolloff spectrum
  1. The smaller the rolloff factor  $r$,  the slower the decay of the Nyquist pulse. This statement is true for both the trapezoidal and the cosine rolloff spectra.
  2. In the limiting case  $r \to 0$,  both cases yield the rectangular Nyquist spectrum and the  $\rm sinc$–shaped Nyquist pulse,   which decays asymptotically with  $1/t$  (thin green curves).
  3. For an average rolloff  $(r \approx 0.5)$,  the first overshoots are smaller for the trapezoidal spectrum than for the CRO spectrum,  because here the Nyquist slope is flatter for a given  $r$  (blue curves).
  4. With the rolloff factor  $r = 1$,  the trapezoid becomes a triangle in the frequency domain and the CRO spectrum becomes the  "cosine–square spectrum".  In the diagrams in the  "last section"  these spectral functions are drawn in red.
  5. With  $r = 1$  the asymptotically decay of the upper time function  (according to the trapezoidal spectrum)  occurs with  $1/t^2$,  the decay of the lower function  (according to the CRO spectrum)  with  $1/t^3$.
  6. This means:   After a longer time,  the CRO Nyquist pulse has settled better than the trapezoidal Nyquist pulse.


Second Nyquist criterion


Before the exact mathematical definition,  the significance of the  second Nyquist criterion  for the evaluation of a digital system is illustrated by means of diagrams. The graphic shows three examples of Nyquist systems,  in each case:

  • at the top,  the Nyquist spectrum  $G_d(f)$,
  • below the corresponding  "eye diagram"  referring to the  "third main chapter".
Clarification of first and second Nyquist criterion


$\text{Interpretation:}$

  • The diagram on the left shows the eye diagram of a Nyquist system with cosine rolloff characteristic,  where the rolloff factor  $r= 0.5$  was chosen.  Since the first Nyquist criterion is fulfilled here  (there is point symmetry around the Nyquist frequency  $f_{\rm Nyq}$,  the vertical eye opening at time  $t = 0$  is  $2 \cdot g_d(0)$.  All eye lines pass at time  $t = 0$  through one of the two points marked in red   ⇒   the eye is vertically maximally open.


  • The middle spectrum does not show any symmetry with respect to the rolloff,  so that the first Nyquist criterion is not fulfilled here – in contrast to the second one.  All eyelines here intersect the time axis at the same times  (marked by the green dots),  which facilitates,  for example,  clock recovery by means of a  $\rm PLL$  ("Phase-Locked Loop").  When the second Nyquist criterion is met,  the horizontal eye opening is maximally equal to the symbol duration $T$   ⇒   the eye is maximally open horizontally.


  • The right eye diagram illustrates that for the CRO spectrum with  $r = 1$,  both the first and second Nyquist criteria are satisfied.  Here,  the Nyquist pulse
$$g_d ( t )= g_0 \cdot \frac{\pi }{4}\cdot {\rm sinc} \left ( \frac{ t}{T}\right)\cdot \left [ {\rm sinc} (\frac{t}{T} + \frac{1}{2}) + {\rm sinc} (\frac{t}{T} - \frac{1}{2})\right]$$
exhibits the required zero crossings at  $t = \pm T$,  $t = \pm 1.5T$,  $t = \pm 2T$,  $t = \pm 2.5T$, ... but not at  $t = \pm 0.5T$. The pulse amplitude is  $g_d(t = 0) = g_0$.    
Note:   No other pulse satisfies both the first and second Nyquist criteria simultaneously.


$\text{Summary of Nyquist criteria:}$

(1)   In memory of the physicist  "Harry Nyquist"  we denote a basic detection pulse  $g_d( t)$  with the properties

$$g_d ( t= 0) \ne 0, \hspace{1cm} g_d ( t)= 0 \hspace{0.3cm}{\rm{for} }\hspace{0.3cm} t = \pm T, \pm 2T,\pm 3T,\hspace{0.05cm}\text{...}$$
as the  Nyquist–1 pulse  $g_{\hspace{0.05cm}\rm Nyq-1}(t)$.  This satisfies the first Nyquist criterion and leads to the maximum vertical eye opening.

(2)   A basic detection pulse  $g_d( t)$  satisfying the second Nyquist criterion must have zero crossings at  $t = \pm 1.5T$,  $t = \pm 2.5T$, ...  have:

$$g_d ( t= 0.5) \ne 0, \hspace{0.8cm} g_d ( t)= 0 \hspace{0.3cm}{\rm{for} }\hspace{0.3cm} t = \pm 1.5T, \ \pm 2.5T,\ \pm 3.5T,\hspace{0.05cm}\text{...}$$
Such a  Nyquist–2 pulse  leads to the maximum horizontal eye opening.

(3)   A Nyquist–2 pulse can always be represented as the sum of two Nyquist–1 pulses shifted by  $t = \pm T/2$: 

$$g_{\rm Nyq-2} ( t )= g_{\rm Nyq-1} ( t +T/2)+g_{\rm Nyq-1} ( t -T/2)\hspace{0.05cm}.$$

(4)   In the frequency domain,  the second Nyquist criterion  (see [TS87] [1]) is:

$$\sum_{k = -\infty}^{+\infty} \frac {G_d \left ( f -k/T \right)}{\cos(\pi \cdot f \cdot T - k \cdot \pi)}= {\rm const.}$$


$\text{Example 3:}$  Starting from the Nyquist–1 pulse  $g_{\rm Nyq-1}( t )= g_0 \cdot {\rm sinc}(t/T)$  the corresponding Nyquist–2 pulse is:

$$g_{\rm Nyq-2}( t ) = g_0 \cdot \left [ {\rm sinc}( \frac{t + T/2}{T}) + {\rm sinc}( \frac{t- T/2}{T}) \right] =\frac{2 \cdot g_0}{\pi} \cdot \frac{\cos(\pi \cdot t/T)}{1 - (2 \cdot t/T)^2}\hspace{0.05cm}.$$
  • Due to the limitation of the spectrum  $G_{\rm Nyq-1}( f)$  to the range  $\vert f \vert \le f_{\rm Nyq} = 1/(2T)$,  the sum in equation  (4)  is limited to the term with  $k = 0$,  and we obtain:
$$G_{\rm Nyq-2}(f) = \left\{ \begin{array}{c} g_0 \cdot T \cdot \cos(\pi/2 \cdot f/f_{\rm Nyq}) \\ \\ 0 \\\end{array} \right.\quad \begin{array}{*{1}c} {\rm{for} }\hspace{0.15cm} \vert f \vert < f_{\rm Nyq}\hspace{0.05cm}, \\ \\ {\rm{otherwise} }\hspace{0.05cm}. \\ \end{array}$$
  • This frequency response and the corresponding eye diagram is sketched in the middle column of the above diagram.
  • From the bottom diagram, one can clearly see the fulfillment of the second Nyquist criterion.


Exercises for the chapter


Exercise 1.4: Nyquist Criteria

Exercise 1.4Z: Complex Nyquist Spectrum

Exercise 1.5: Cosine-Square Spectrum

References

  1. Tröndle, K.; Söder, G.:  Optimization of Digital Transmission Systems.  Boston – London:  Artech House, 1987.