Difference between revisions of "Aufgaben:Exercise 4.1Z: High-Pass System"

From LNTwww
 
(5 intermediate revisions by 2 users not shown)
Line 1: Line 1:
  
{{quiz-Header|Buchseite=Signal Representation/Differences and Similarities of LP and BP Signals
+
{{quiz-Header|Buchseite=Signal_Representation/Differences_and_Similarities_of_Low-Pass_and_Band-Pass_Signals
 
}}
 
}}
  
[[File:EN_Sig_Z_4_1.png|right|frame|Examples for low-pass and high-pass]]
+
[[File:EN_Sig_Z_4_1.png|right|frame|Simplest examples for <br>"low-pass" and "high-pass"]]
The relationships shown on the page&nbsp; [[Signal_Representation/Differences_and_Similarities_of_LP_and_BP_Signals#Properties_of_BP-Signals|Properties of Bandpass Signals]]&nbsp; apply not only to signals and spectra, but also in the same way to  
+
The relationships shown in the section&nbsp; [[Signal_Representation/Differences_and_Similarities_of_LP_and_BP_Signals#Properties_of_BP-Signals|"Properties of Bandpass Signals"]]&nbsp; apply not only to signals and spectra, but in the same way to  
 
*the frequency response&nbsp; $H(f)$&nbsp; and  
 
*the frequency response&nbsp; $H(f)$&nbsp; and  
*the impulse response&nbsp; $h(t)$  
+
*the impulse response&nbsp; $h(t)$&nbsp;  of an LTI system.
  
  
of an LTI system. These are also related via the&nbsp; [[Signal_Representation/Fourier_Transform_and_Its_Inverse|Fourier Transform]]&nbsp;. More information on this can be found in the book&nbsp; [[Linear and timeinvariant systems]].
+
These are also related via the&nbsp; [[Signal_Representation/Fourier_Transform_and_Its_Inverse|Fourier Transform]].&nbsp; More information can be found in the book&nbsp; [[Linear_and_Time_Invariant_Systems|"Linear and Time-Invariant Systems"]].
  
The circuit shown in the upper diagram is the simplest realisation of a low-pass filter:
+
The circuit shown in the upper diagram is the simplest realisation of a low-pass&nbsp; (German:&nbsp; "Tiefpass" &nbsp; &rArr; &nbsp; $\text{TP}$)&nbsp; filter:
 
*For very high frequencies, the capacitance&nbsp; $C$&nbsp; acts as a short circuit, so that high-frequency components are no longer included in the output signal.
 
*For very high frequencies, the capacitance&nbsp; $C$&nbsp; acts as a short circuit, so that high-frequency components are no longer included in the output signal.
 
*In contrast, low-frequency signal components are only imperceptibly attenuated by the voltage divider.  
 
*In contrast, low-frequency signal components are only imperceptibly attenuated by the voltage divider.  
*With the 3dB&ndash;cut-off frequency&nbsp; $f_{\rm G}$&nbsp;, the following applies to the frequency response:
+
*With the 3dB cut-off frequency&nbsp; $f_{\rm G}$&nbsp; the following applies to the frequency response:
 
:$$H_{\rm TP}(f) = \frac{1}{1 + {\rm j} \cdot f / f_{\rm G}}  =
 
:$$H_{\rm TP}(f) = \frac{1}{1 + {\rm j} \cdot f / f_{\rm G}}  =
 
|H_{\rm TP}(f)|\cdot {\rm e}^{-{\rm j}\hspace{0.05cm}\cdot \hspace{0.05cm} \varphi_{\rm TP}(f)} .$$
 
|H_{\rm TP}(f)|\cdot {\rm e}^{-{\rm j}\hspace{0.05cm}\cdot \hspace{0.05cm} \varphi_{\rm TP}(f)} .$$
  
In the second part of the equation, the frequency response&nbsp; $H_{\rm TP}(f)$&nbsp; is split according to magnitude and phase.
+
In the second part of this equation, the frequency response&nbsp; $H_{\rm TP}(f)$&nbsp; is split according to magnitude and phase.
  
The impulse response&nbsp; $h_{\rm TP}(t)$&nbsp; is obtained by Fourier transformation of&nbsp; $H_{\rm TP}(f)$, where the time constant&nbsp; $\tau = R \cdot C = {1}/({2\pi \cdot f_{\rm G}}) $&nbsp; is to be set.  
+
The impulse response&nbsp; $h_{\rm TP}(t)$&nbsp; is obtained by Fourier transform of&nbsp; $H_{\rm TP}(f)$, where the constant&nbsp; $\tau = R \cdot C = {1}/({2\pi \cdot f_{\rm G}}) $.  
  
For&nbsp; $t < 0$&nbsp; the impulse response is identically zero, for positive times:
+
For&nbsp; $t < 0$&nbsp; the impulse response is identically zero,&nbsp; anf for positive times:
 
:$$h_{\rm TP}(t) = \frac{1}{\tau} \cdot {\rm e}^{-t / \tau} .$$
 
:$$h_{\rm TP}(t) = \frac{1}{\tau} \cdot {\rm e}^{-t / \tau} .$$
  
 
The circuit shown below describes a high-pass filter whose frequency response&nbsp; $H_{\rm HP}(f)$&nbsp; and impulse response&nbsp; $h_{\rm HP}(t)$&nbsp; are to be determined in this task. Such a high-pass can also be interpreted as a limiting case of a band-pass.
 
The circuit shown below describes a high-pass filter whose frequency response&nbsp; $H_{\rm HP}(f)$&nbsp; and impulse response&nbsp; $h_{\rm HP}(t)$&nbsp; are to be determined in this task. Such a high-pass can also be interpreted as a limiting case of a band-pass.
 
 
 
 
  
  
Line 35: Line 31:
  
 
''Hints:''  
 
''Hints:''  
*The task belongs to the chapter&nbsp; [[Signal_Representation/Differences_and_Similarities_of_LP_and_BP_Signals|Differences and Similarities of Lowpass and Bandpass Signals]].
+
*This exercise belongs to the chapter&nbsp; [[Signal_Representation/Differences_and_Similarities_of_Low-Pass_and_Band-Pass_Signals|Differences and Similarities of Low-Pass and Band-Pass Signals]].
 
   
 
   
  
Line 43: Line 39:
  
 
<quiz display=simple>
 
<quiz display=simple>
{Which of the following statements are true for the TP system??
+
{Which of the following statements are true for the low-pass system??
 
|type="[]"}
 
|type="[]"}
- Der Gleichsignalübertragungsfaktor beträgt&nbsp; $H_{\rm TP}(f = 0) = 2$.
+
- The DC transmission factor is&nbsp; $H_{\rm TP}(f = 0) = 2$.
+ $|H_{\rm TP}(f)|$&nbsp; is smaller by&nbsp; $f = f_{\rm G}$&nbsp; um&nbsp; $\sqrt{2}$&nbsp; than at&nbsp; $f = 0$.
+
+ $|H_{\rm TP}(f= f_{\rm G})|$&nbsp; is smaller by&nbsp; $\sqrt{2}$&nbsp; than&nbsp; $|H_{\rm TP}(f= 0)|$.
+ The phase function is: &nbsp; $\varphi_{\rm TP}(f) = \arctan(f/f_{\rm G})$.
+
+ The phase function is&nbsp; $\varphi_{\rm TP}(f) = \arctan(f/f_{\rm G})$.
  
  
{Justify why&nbsp; $H_{\rm HP}(f) = 1 - H_{\rm TP}(f)$&nbsp; must always hold. Calculate&nbsp; $H_{\rm HP}(f)$, in particular the value at&nbsp; $f = 0$.
+
{Justify why&nbsp; $H_{\rm HP}(f) = 1 - H_{\rm TP}(f)$&nbsp; must always hold.&nbsp; Calculate&nbsp; $H_{\rm HP}(f)$,&nbsp; in particular the value at&nbsp; $f = 0$.
 
|type="{}"}
 
|type="{}"}
 
$H_{\rm HP}(f = 0)\ = \ $ { 0. }
 
$H_{\rm HP}(f = 0)\ = \ $ { 0. }
  
  
{Which of the following statements is true?
+
{Which of the following statements are true?
 
|type="[]"}
 
|type="[]"}
- Es gilt &nbsp;$|H_{\rm HP}(f = f_{\rm G})| = 1 - |H_{\rm TP}(f = f_{\rm G})|$ is true.
+
- It holds: &nbsp;$|H_{\rm HP}(f = f_{\rm G})| = 1 - |H_{\rm TP}(f = f_{\rm G})|$.
+ Es gilt &nbsp;$|H_{\rm HP}(f = f_{\rm G})| = |H_{\rm TP}(f = f_{\rm G})|$ is true.
+
+ It holds: &nbsp;$|H_{\rm HP}(f = f_{\rm G})| = |H_{\rm TP}(f = f_{\rm G})|$.
 
+ For positive frequencies it holds: &nbsp; $\varphi_{\rm HP}(f) = \varphi_{\rm TP}(f) - \pi/2$.
 
+ For positive frequencies it holds: &nbsp; $\varphi_{\rm HP}(f) = \varphi_{\rm TP}(f) - \pi/2$.
  
  
{Calculate the impulse response&nbsp; $h_{\rm  TP}(t)$. Interpret the result. Which of the following statements are correct?
+
{Calculate the impulse response&nbsp; $h_{\rm  TP}(t)$.&nbsp; Interpret the result.&nbsp; Which of the following statements are correct?
 
|type="[]"}
 
|type="[]"}
- &nbsp;$h_{\rm HP}(t) = \tau/t \cdot {\rm e}^{-t/\tau}$ is true.
+
- It holds: &nbsp;$h_{\rm HP}(t) = \tau/t \cdot {\rm e}^{-t/\tau}$.
+ &nbsp;$h_{\rm HP}(t) = \delta (t) - 1/\tau \cdot {\rm e}^{-t/\tau}$ is true.
+
+ It holds: &nbsp;$h_{\rm HP}(t) = \delta (t) - 1/\tau \cdot {\rm e}^{-t/\tau}$.
 
+ At time&nbsp; $t = 0$&nbsp; the impulse response is infinite.
 
+ At time&nbsp; $t = 0$&nbsp; the impulse response is infinite.
- At time&nbsp; $t = \tau$&nbsp; the impulse response is equal to. ${\rm e}/\tau$.
+
- At time&nbsp; $t = \tau$&nbsp; the impulse response is equal to&nbsp; ${\rm e}/\tau$.
  
  
Line 75: Line 71:
 
{{ML-Kopf}}
 
{{ML-Kopf}}
 
'''(1)'''&nbsp;  The correct <u> solutions are 2 and 3</u>:
 
'''(1)'''&nbsp;  The correct <u> solutions are 2 and 3</u>:
*Der Gleichsignalübertragungsfaktor ist&nbsp; $H_{\rm TP}(f = 0) = 1$.  
+
*The DC transmission factor is&nbsp;&nbsp; $H_{\rm TP}(f = 0) = 1$.  
 
*For the magnitude frequency response holds:
 
*For the magnitude frequency response holds:
 
:$$|H_{\rm TP}(f)| = \frac{1}{\sqrt{1 + ( f / f_{\rm G})^2}} .$$
 
:$$|H_{\rm TP}(f)| = \frac{1}{\sqrt{1 + ( f / f_{\rm G})^2}} .$$
*Thus, the value at&nbsp; $f_{\rm G}$ is equal to $\sqrt{1/2}$. The power transfer function&nbsp; $|H_{\rm TP}(f)|^2$&nbsp; is therefore only half as large at&nbsp; $f = f_{\rm G}$&nbsp; as at&nbsp; $f = 0$, which is the reason for the designation &bdquo;3dB&ndash;cut-off frequency&rdquo; for&nbsp; $f_{\rm G}$&nbsp;.
+
*Thus, the value at&nbsp; $f_{\rm G}$ is equal to $\sqrt{1/2}$.&nbsp; The power transfer function&nbsp; $|H_{\rm TP}(f)|^2$&nbsp; is therefore only half as large at&nbsp; $f = f_{\rm G}$&nbsp; as at&nbsp; $f = 0$, which is the reason for the designation "3dB cut-off frequency".
 
*The phase function is generally calculated according to the following equation:
 
*The phase function is generally calculated according to the following equation:
 
:$$\varphi_{\rm TP}(f) = -\arctan\frac{{\rm Im}\left[H_{\rm
 
:$$\varphi_{\rm TP}(f) = -\arctan\frac{{\rm Im}\left[H_{\rm
Line 91: Line 87:
  
  
'''(2)'''&nbsp; On the page [[Signal_Representation/Differences_and_Similarities_of_LP_and_BP_Signals#Properties_of_BP-Signals|Properties of Bandpass Signals]]it was shown that any band-pass signal can be represented as the difference of two low-pass signals.
+
'''(2)'''&nbsp; In the section&nbsp; "Properties of Bandpass Signals"&nbsp; it was shown that any band-pass signal can be represented as the difference of two low-pass signals.
  
[[File:P_ID703__Sig_Z_4_1_b.png|right|frame|Low-pass and high-pass spectrum]]
+
[[File:P_ID703__Sig_Z_4_1_b.png|right|frame|Red:&nbsp; Low-pass&nbsp; $\rm (TP)$,<br>Blue:&nbsp; High-pass&nbsp; $\rm (HP)$]]
 
The same applies to frequency responses:
 
The same applies to frequency responses:
 
:$$H_{\rm BP}(f) = H_1(f) - H_2(f).$$
 
:$$H_{\rm BP}(f) = H_1(f) - H_2(f).$$
 
*If we set&nbsp; $H_2(f) = H_{\rm TP}(f)$&nbsp; and consider&nbsp; $H_1(f) = 1$&nbsp; as the limiting case of a low-pass function with an infinitely large bandwidth, we get:
 
*If we set&nbsp; $H_2(f) = H_{\rm TP}(f)$&nbsp; and consider&nbsp; $H_1(f) = 1$&nbsp; as the limiting case of a low-pass function with an infinitely large bandwidth, we get:
 
:$$H_{\rm HP}(f) = 1 - H_{\rm TP}(f).$$
 
:$$H_{\rm HP}(f) = 1 - H_{\rm TP}(f).$$
*As the graph shows, the result is now a high-pass because of &nbsp; $H_1(f) = 1$&nbsp;. With the given low-pass function&nbsp; $H_{\rm TP}(f)$&nbsp; one further obtains:
+
*As the graph shows, the result is now a high-pass because of &nbsp; $H_1(f) = 1$.&nbsp; With the given low-pass function&nbsp; $H_{\rm TP}(f)$&nbsp; one further obtains:
 
:$$H_{\rm HP}(f) = 1 - \frac{1}{1 + {\rm j} \cdot f / f_{\rm G}}  =
 
:$$H_{\rm HP}(f) = 1 - \frac{1}{1 + {\rm j} \cdot f / f_{\rm G}}  =
 
\frac{{\rm j} \cdot f / f_{\rm G}}{1 + {\rm j} \cdot f / f_{\rm
 
\frac{{\rm j} \cdot f / f_{\rm G}}{1 + {\rm j} \cdot f / f_{\rm
 
G}} .$$
 
G}} .$$
*For&nbsp; $f = 0$&nbsp; &nbsp; $H_{\rm HP}(f = 0) \;\underline{= 0}$ is obtained. Note that it is the actual (complex) function&nbsp; $H_{\rm TP}(f)$&nbsp; and not its magnitude that is to be subtracted. Therefore, the above sketch is to be understood only qualitatively.
+
*For&nbsp; $f = 0$:&nbsp; &nbsp; $H_{\rm HP}(f = 0) \;\underline{= 0}$ is obtained.&nbsp; Note that it is the actual (complex) function&nbsp; $H_{\rm TP}(f)$&nbsp; and not its magnitude that is to be subtracted.&nbsp; Therefore, the above sketch is to be understood only qualitatively.
  
  
One arrives at exactly the same result starting from the concrete circuit on the information page. Corresponding to a frequency-dependent voltage divider with resistors&nbsp; $R$&nbsp; and&nbsp; $1/(j\omega C)$&nbsp; applies:
+
One arrives at exactly the same result starting from the concrete circuit in the information section.&nbsp; Corresponding to a frequency-dependent voltage divider with resistors&nbsp; $R$&nbsp; and&nbsp; $1/(j\omega C)$&nbsp; applies:
 
:$$H_{\rm HP}(f) =  \frac{R}{R + 1/({\rm j}\cdot \omega \cdot C)} =
 
:$$H_{\rm HP}(f) =  \frac{R}{R + 1/({\rm j}\cdot \omega \cdot C)} =
 
\frac{{\rm j}\cdot \omega \cdot C \cdot R}{1+{\rm j} \cdot \omega
 
\frac{{\rm j}\cdot \omega \cdot C \cdot R}{1+{\rm j} \cdot \omega
Line 113: Line 109:
  
  
'''(3)'''&nbsp; : The correct <u>solutions are 2 and 3</u>:
+
'''(3)'''&nbsp; The correct <u>solutions are 2 and 3</u>:
 
*The magnitude function of the high-pass is:
 
*The magnitude function of the high-pass is:
 
:$$|H_{\rm HP}(f)| = \frac{|f / f_{\rm G}|}{\sqrt{1 + ( f / f_{\rm
 
:$$|H_{\rm HP}(f)| = \frac{|f / f_{\rm G}|}{\sqrt{1 + ( f / f_{\rm
 
G})^2}} .$$
 
G})^2}} .$$
*At the cut-off frequency&nbsp; $f_{\rm G}$&nbsp; , the magnitudes of the high-pass and low-pass frequency response are thus equal, namely&nbsp; $0.707$ each.  
+
*At the cut-off frequency&nbsp; $f_{\rm G}$,&nbsp; the magnitudes of the high-pass and low-pass frequency response are thus equal, namely&nbsp; $0.707$ each.  
*On the other hand, the first statement is obviously wrong:&nbsp; According to this, the value&nbsp; $|H_{HP}(f = f_{\rm G})| = 1 0.707 \approx 0.293$&nbsp; should result.
+
*On the other hand, the first statement is obviously wrong: &nbsp; According to this, the value&nbsp; $|H_{HP}(f = f_{\rm G})| = 1 - 0.707 \approx 0.293$&nbsp; should result.
[[File:EN_Sig_Z_4_1_c.png|right|frame|Low-pass and high-pass phase response]]
+
[[File:EN_Sig_Z_4_1_c.png|right|frame|Phase responses of <br>low-pass and high-pass ]]
 
*The frequency response calculated under&nbsp; '''(2)'''&nbsp; can also be represented as follows:
 
*The frequency response calculated under&nbsp; '''(2)'''&nbsp; can also be represented as follows:
 
:$$H_{\rm HP}(f) = \frac{( f / f_{\rm G})^2 + {\rm j} \cdot f /
 
:$$H_{\rm HP}(f) = \frac{( f / f_{\rm G})^2 + {\rm j} \cdot f /
 
f_{\rm G}}{{1 + ( f / f_{\rm G})^2}} .$$
 
f_{\rm G}}{{1 + ( f / f_{\rm G})^2}} .$$
:This gives for the phase function:
+
*This gives for the phase function:
 
:$$\varphi_{\rm HP}(f) =-\arctan\frac{f / f_{\rm G}}{( f /
 
:$$\varphi_{\rm HP}(f) =-\arctan\frac{f / f_{\rm G}}{( f /
 
f_{\rm G})^2}=  
 
f_{\rm G})^2}=  
Line 129: Line 125:
 
:$$\Rightarrow \hspace{0.3cm}\varphi_{\rm HP}(f)  =  {\rm arctan} (\frac{f}{f_{\rm G}}) - \frac{\pi}{2}= \varphi_{\rm TP}(f)- \frac{\pi}{2}.$$
 
:$$\Rightarrow \hspace{0.3cm}\varphi_{\rm HP}(f)  =  {\rm arctan} (\frac{f}{f_{\rm G}}) - \frac{\pi}{2}= \varphi_{\rm TP}(f)- \frac{\pi}{2}.$$
  
*At positive frequencies, therefore, the same course as with the low-pass system results, except for a shift of&nbsp; $\pi /2$&nbsp; downwards. Since the phase function is odd, there is an upward shift of&nbsp; $\pi /2$&nbsp; at negative frequencies.
+
*Therefore:&nbsp; At positive frequencies, the same course as with the low-pass system results, except for a shift of&nbsp; $\pi /2$&nbsp; downwards.&nbsp; Since the phase function is odd, there is an upward shift of&nbsp; $\pi /2$&nbsp; at negative frequencies.
  
  
Line 135: Line 131:
  
 
'''(4)'''&nbsp; Proposed <u>solutions 2 and 3</u> are correct:
 
'''(4)'''&nbsp; Proposed <u>solutions 2 and 3</u> are correct:
*Due to the linearity of the (inverse) Fourier transformation, the following applies to the time course for&nbsp; $t > 0$:
+
*Due to the linearity of the (inverse) Fourier transform, the following applies to the time course for&nbsp; $t > 0$:
 
:$$h_{\rm HP}(t) = h_1(t) - h_2(t)= \delta(t) - \frac{1}{\tau}\cdot
 
:$$h_{\rm HP}(t) = h_1(t) - h_2(t)= \delta(t) - \frac{1}{\tau}\cdot
 
{\rm e}^{-t / \tau} .$$
 
{\rm e}^{-t / \tau} .$$
 
*The Dirac function is the inverse Fourier transform of the constant frequency function „1”.  
 
*The Dirac function is the inverse Fourier transform of the constant frequency function „1”.  
*The second component is identical to the LP impulse response except for the sign.
+
*The second component is identical to the low-pass impulse response except for the sign.
*The Dirac function causes&nbsp; $h_{\rm HP}(t)$&nbsp; to be infinitely large at time&nbsp; $t = 0$&nbsp;.In contrast, the following applies for&nbsp; $t = \tau$:
+
*The Dirac function causes&nbsp; $h_{\rm HP}(t)$&nbsp; to be infinitely large at time&nbsp; $t = 0$.&nbsp; In contrast, the following applies for&nbsp; $t = \tau$:
 
:$$h_{\rm HP}(t = \tau) =  - \frac{1}{\tau}\cdot {\rm e}^{-1} =  -
 
:$$h_{\rm HP}(t = \tau) =  - \frac{1}{\tau}\cdot {\rm e}^{-1} =  -
{{\rm e}\cdot \tau}^{-1}.$$
+
{{\rm e}/ \tau}.$$
 
*The last statement is therefore also false due to the sign.
 
*The last statement is therefore also false due to the sign.
 
{{ML-Fuß}}
 
{{ML-Fuß}}
Line 148: Line 144:
  
 
__NOEDITSECTION__
 
__NOEDITSECTION__
[[Category:Signal Representation: Exercises|^4.1 Differences/Similarities of LP and BP Signals^]]
+
[[Category:Signal Representation: Exercises|^4.1 Differences between Low-Pass and Band-Pass^]]

Latest revision as of 13:48, 17 November 2022

Simplest examples for
"low-pass" and "high-pass"

The relationships shown in the section  "Properties of Bandpass Signals"  apply not only to signals and spectra, but in the same way to

  • the frequency response  $H(f)$  and
  • the impulse response  $h(t)$  of an LTI system.


These are also related via the  Fourier Transform.  More information can be found in the book  "Linear and Time-Invariant Systems".

The circuit shown in the upper diagram is the simplest realisation of a low-pass  (German:  "Tiefpass"   ⇒   $\text{TP}$)  filter:

  • For very high frequencies, the capacitance  $C$  acts as a short circuit, so that high-frequency components are no longer included in the output signal.
  • In contrast, low-frequency signal components are only imperceptibly attenuated by the voltage divider.
  • With the 3dB cut-off frequency  $f_{\rm G}$  the following applies to the frequency response:
$$H_{\rm TP}(f) = \frac{1}{1 + {\rm j} \cdot f / f_{\rm G}} = |H_{\rm TP}(f)|\cdot {\rm e}^{-{\rm j}\hspace{0.05cm}\cdot \hspace{0.05cm} \varphi_{\rm TP}(f)} .$$

In the second part of this equation, the frequency response  $H_{\rm TP}(f)$  is split according to magnitude and phase.

The impulse response  $h_{\rm TP}(t)$  is obtained by Fourier transform of  $H_{\rm TP}(f)$, where the constant  $\tau = R \cdot C = {1}/({2\pi \cdot f_{\rm G}}) $.

For  $t < 0$  the impulse response is identically zero,  anf for positive times:

$$h_{\rm TP}(t) = \frac{1}{\tau} \cdot {\rm e}^{-t / \tau} .$$

The circuit shown below describes a high-pass filter whose frequency response  $H_{\rm HP}(f)$  and impulse response  $h_{\rm HP}(t)$  are to be determined in this task. Such a high-pass can also be interpreted as a limiting case of a band-pass.



Hints:



Questions

1

Which of the following statements are true for the low-pass system??

The DC transmission factor is  $H_{\rm TP}(f = 0) = 2$.
$|H_{\rm TP}(f= f_{\rm G})|$  is smaller by  $\sqrt{2}$  than  $|H_{\rm TP}(f= 0)|$.
The phase function is  $\varphi_{\rm TP}(f) = \arctan(f/f_{\rm G})$.

2

Justify why  $H_{\rm HP}(f) = 1 - H_{\rm TP}(f)$  must always hold.  Calculate  $H_{\rm HP}(f)$,  in particular the value at  $f = 0$.

$H_{\rm HP}(f = 0)\ = \ $

3

Which of the following statements are true?

It holds:  $|H_{\rm HP}(f = f_{\rm G})| = 1 - |H_{\rm TP}(f = f_{\rm G})|$.
It holds:  $|H_{\rm HP}(f = f_{\rm G})| = |H_{\rm TP}(f = f_{\rm G})|$.
For positive frequencies it holds:   $\varphi_{\rm HP}(f) = \varphi_{\rm TP}(f) - \pi/2$.

4

Calculate the impulse response  $h_{\rm TP}(t)$.  Interpret the result.  Which of the following statements are correct?

It holds:  $h_{\rm HP}(t) = \tau/t \cdot {\rm e}^{-t/\tau}$.
It holds:  $h_{\rm HP}(t) = \delta (t) - 1/\tau \cdot {\rm e}^{-t/\tau}$.
At time  $t = 0$  the impulse response is infinite.
At time  $t = \tau$  the impulse response is equal to  ${\rm e}/\tau$.


Solution

(1)  The correct solutions are 2 and 3:

  • The DC transmission factor is   $H_{\rm TP}(f = 0) = 1$.
  • For the magnitude frequency response holds:
$$|H_{\rm TP}(f)| = \frac{1}{\sqrt{1 + ( f / f_{\rm G})^2}} .$$
  • Thus, the value at  $f_{\rm G}$ is equal to $\sqrt{1/2}$.  The power transfer function  $|H_{\rm TP}(f)|^2$  is therefore only half as large at  $f = f_{\rm G}$  as at  $f = 0$, which is the reason for the designation "3dB cut-off frequency".
  • The phase function is generally calculated according to the following equation:
$$\varphi_{\rm TP}(f) = -\arctan\frac{{\rm Im}\left[H_{\rm TP}(f)\right]}{{\rm Re}\left[H_{\rm TP}(f)\right]} .$$
  • With the conjugate-complex expansion one obtains:
$$H_{\rm TP}(f) = \frac{1}{1 - ( f / f_{\rm G})^2} - \frac{{\rm j} \cdot f / f_{\rm G}}{1 - ( f / f_{\rm G})^2}.$$
  • Substituting this result into the above equation gives:
$$\varphi_{\rm TP}(f) = \arctan\left(f / f_{\rm G}\right) .$$
  • The progression is monotonically increasing from  $0$  $($at  $f = 0)$  via  $\pi/2$  $($at  $f = f_{\rm G})$  to  $\pi$  $($bei  $f \rightarrow \infty)$ .


(2)  In the section  "Properties of Bandpass Signals"  it was shown that any band-pass signal can be represented as the difference of two low-pass signals.

Red:  Low-pass  $\rm (TP)$,
Blue:  High-pass  $\rm (HP)$

The same applies to frequency responses:

$$H_{\rm BP}(f) = H_1(f) - H_2(f).$$
  • If we set  $H_2(f) = H_{\rm TP}(f)$  and consider  $H_1(f) = 1$  as the limiting case of a low-pass function with an infinitely large bandwidth, we get:
$$H_{\rm HP}(f) = 1 - H_{\rm TP}(f).$$
  • As the graph shows, the result is now a high-pass because of   $H_1(f) = 1$.  With the given low-pass function  $H_{\rm TP}(f)$  one further obtains:
$$H_{\rm HP}(f) = 1 - \frac{1}{1 + {\rm j} \cdot f / f_{\rm G}} = \frac{{\rm j} \cdot f / f_{\rm G}}{1 + {\rm j} \cdot f / f_{\rm G}} .$$
  • For  $f = 0$:    $H_{\rm HP}(f = 0) \;\underline{= 0}$ is obtained.  Note that it is the actual (complex) function  $H_{\rm TP}(f)$  and not its magnitude that is to be subtracted.  Therefore, the above sketch is to be understood only qualitatively.


One arrives at exactly the same result starting from the concrete circuit in the information section.  Corresponding to a frequency-dependent voltage divider with resistors  $R$  and  $1/(j\omega C)$  applies:

$$H_{\rm HP}(f) = \frac{R}{R + 1/({\rm j}\cdot \omega \cdot C)} = \frac{{\rm j}\cdot \omega \cdot C \cdot R}{1+{\rm j} \cdot \omega \cdot C \cdot R} = \frac{{\rm j} \cdot f / f_{\rm G}}{1 + {\rm j} \cdot f / f_{\rm G}}.$$


(3)  The correct solutions are 2 and 3:

  • The magnitude function of the high-pass is:
$$|H_{\rm HP}(f)| = \frac{|f / f_{\rm G}|}{\sqrt{1 + ( f / f_{\rm G})^2}} .$$
  • At the cut-off frequency  $f_{\rm G}$,  the magnitudes of the high-pass and low-pass frequency response are thus equal, namely  $0.707$ each.
  • On the other hand, the first statement is obviously wrong:   According to this, the value  $|H_{HP}(f = f_{\rm G})| = 1 - 0.707 \approx 0.293$  should result.
Phase responses of
low-pass and high-pass
  • The frequency response calculated under  (2)  can also be represented as follows:
$$H_{\rm HP}(f) = \frac{( f / f_{\rm G})^2 + {\rm j} \cdot f / f_{\rm G}}{{1 + ( f / f_{\rm G})^2}} .$$
  • This gives for the phase function:
$$\varphi_{\rm HP}(f) =-\arctan\frac{f / f_{\rm G}}{( f / f_{\rm G})^2}= -{\rm arcctg} ({f}/{f_{\rm G}}) $$
$$\Rightarrow \hspace{0.3cm}\varphi_{\rm HP}(f) = {\rm arctan} (\frac{f}{f_{\rm G}}) - \frac{\pi}{2}= \varphi_{\rm TP}(f)- \frac{\pi}{2}.$$
  • Therefore:  At positive frequencies, the same course as with the low-pass system results, except for a shift of  $\pi /2$  downwards.  Since the phase function is odd, there is an upward shift of  $\pi /2$  at negative frequencies.



(4)  Proposed solutions 2 and 3 are correct:

  • Due to the linearity of the (inverse) Fourier transform, the following applies to the time course for  $t > 0$:
$$h_{\rm HP}(t) = h_1(t) - h_2(t)= \delta(t) - \frac{1}{\tau}\cdot {\rm e}^{-t / \tau} .$$
  • The Dirac function is the inverse Fourier transform of the constant frequency function „1”.
  • The second component is identical to the low-pass impulse response except for the sign.
  • The Dirac function causes  $h_{\rm HP}(t)$  to be infinitely large at time  $t = 0$.  In contrast, the following applies for  $t = \tau$:
$$h_{\rm HP}(t = \tau) = - \frac{1}{\tau}\cdot {\rm e}^{-1} = - {{\rm e}/ \tau}.$$
  • The last statement is therefore also false due to the sign.