Difference between revisions of "Aufgaben:Exercise 4.6Z: ISDN Supply Lines"
From LNTwww
Line 1: | Line 1: | ||
− | {{quiz-Header|Buchseite= | + | {{quiz-Header|Buchseite=Linear_and_Time_Invariant_Systems/Properties_of_Balanced_Copper_Pairs |
}} | }} | ||
− | [[File:EN_LZI_Z_4_6.png|right|frame| | + | [[File:EN_LZI_Z_4_6.png|right|frame|Main bundle, basic bundle and four-wire line]] |
− | + | In [[Examples_of_Communication_Systems/Allgemeine_Beschreibung_von_ISDN|$\rm ISDN$]] (''Integrated Services Digital Networks''), the terminal (near the subscriber) is connected to a local exchange (OVSt) by a copper pair, with two pairs twisted into a so-called four-wire line. | |
− | * | + | *Several such four-wire line pairs are twisted to form a basic bundle, |
− | * | + | *several basic bundles are combined to form a main bundle (see diagram). |
− | + | In the network of Deutschen Telekom (formerly: Deutsche Bundespost), mostly copper lines with $\text{0.4 mm}$ core diameter, are found, for whose attenuation and phase function given in [PW95] are the following equations: | |
:$${{a}_{\rm K}(f)}/{\rm dB} = \left [ 5.1 + 14.3 \cdot \left ({f}/{\rm MHz}\right )^{0.59}\right ]\cdot{l}/{\rm km} | :$${{a}_{\rm K}(f)}/{\rm dB} = \left [ 5.1 + 14.3 \cdot \left ({f}/{\rm MHz}\right )^{0.59}\right ]\cdot{l}/{\rm km} | ||
\hspace{0.05cm},$$ | \hspace{0.05cm},$$ | ||
:$${b_{\rm K}(f)}/{\rm rad} = \left [ 32.9 \cdot ({f}/{\rm MHz}) + 2.26 \cdot \left ({f}/{\rm MHz}\right )^{0.5}\right ]\cdot {l}/{\rm km} | :$${b_{\rm K}(f)}/{\rm rad} = \left [ 32.9 \cdot ({f}/{\rm MHz}) + 2.26 \cdot \left ({f}/{\rm MHz}\right )^{0.5}\right ]\cdot {l}/{\rm km} | ||
\hspace{0.05cm}.$$ | \hspace{0.05cm}.$$ | ||
− | + | Here $l$ denotes the line length. | |
Line 23: | Line 23: | ||
− | '' | + | ''Notes:'' |
− | * | + | *The exercise belongs to the chapter [[Linear_and_Time_Invariant_Systems/Eigenschaften_von_Kupfer–Doppeladern|Properties of Balanced Copper Pairs]]. |
− | * | + | *For more information on the attenuation behavior of copper lines, see [[Examples_of_Communication_Systems/Allgemeine_Beschreibung_von_ISDN#Vierdraht.E2.80.93_und_Zweidraht.C3.BCbertragung|Vierdraht-und Zweidraht-Übertragung]] page in the book "Examples of Communication Systems". |
− | * | + | *You can use the (German language) interactive SWF applet [[Applets:Dämpfung_von_Kupferkabeln|"Dämpfung von Kupferkabeln"]] ⇒ "Attenuation of copper cables" to check your results. |
− | *[PW95] | + | *[PW95] denotes the following literature reference: Pollakowski, P.; Wellhausen, H.-W.: ''Eigenschaften symmetrischer Ortsanschlusskabel im Frequenzbereich bis 30 MHz.'' Deutsche Telekom AG, Forschungs- und Technologiezentrum Darmstadt, 1995. |
− | === | + | ===Questions=== |
<quiz display=simple> | <quiz display=simple> | ||
− | { | + | {How many subscribers $(N)$ can be connected to an ISDN local exchange via the main cable shown at the beginning? |
|type="{}"} | |type="{}"} | ||
$N \ = \ $ { 50 3% } | $N \ = \ $ { 50 3% } | ||
− | { | + | {What are the consequences of two-wire transmission? |
|type="[]"} | |type="[]"} | ||
− | + | + | + The two transmission directions can interfere with each other. |
− | + | + | + Crosstalk interference can occur. |
− | - | + | - Pulse interference occurs. |
− | { | + | {A DC signal is attenuated by a factor of $4$. What is the cable length $l$? |
|type="{}"} | |type="{}"} | ||
$l \ = \ $ { 2.36 3% } $\ \rm km$ | $l \ = \ $ { 2.36 3% } $\ \rm km$ | ||
− | { | + | {What is the attenuation and phase for the frequency $f = 120 \ \rm kHz$? |
|type="{}"} | |type="{}"} | ||
$a_{\rm K}(f = 120\ \rm kHz)\ = \ $ { 21.7 3% } $\ \rm dB$ | $a_{\rm K}(f = 120\ \rm kHz)\ = \ $ { 21.7 3% } $\ \rm dB$ | ||
Line 62: | Line 62: | ||
</quiz> | </quiz> | ||
− | === | + | ===Solution=== |
{{ML-Kopf}} | {{ML-Kopf}} | ||
− | '''(1)''' | + | '''(1)''' Two-wire transmission is used in the connection area. The possible connections are therefore equal to the number of pairs in the main cable: |
:$$N = 5 \cdot 5 \cdot 2 \hspace{0.15cm}\underline{= 50}.$$ | :$$N = 5 \cdot 5 \cdot 2 \hspace{0.15cm}\underline{= 50}.$$ | ||
− | '''(2)''' | + | '''(2)''' <u>Solutions 1 and 2</u> are correct: |
− | * | + | *In two-wire transmission, a direction separation method is required, namely the so-called '''hybrid coil'''. This has the task that at receiver $\rm A$ only the transmitted signal of subscriber $\rm B$ arrives, but not the own transmitted signal. This is generally quite successful with narrow–band signals – for example speech – but not completely ⇒ solution 1 is correct. |
− | * | + | *Solution 2 is also correct. Due to inductive and capacitive couplings, crosstalk can occur from the twin wire located in the same four-wire line, whereby near-end crosstalk (i.e. the interfering transmitter and the interfered receiver are located together) leads to greater impairments than far-end crosstalk. |
− | * | + | *On the other hand, the last solution is not applicable. Pulse interference ⇒ the mutual interfering influence of neighboring symbols can certainly occur, but it is not related to two-wire transmission. The reason for such pulse interference is rather linear distortion, caused by a non-ideal attenuation or phase response. |
− | '''(3)''' | + | '''(3)''' The DC attenuation by a factor of $4$ can be expressed as follows: |
:$$a_{\rm K}(f = 0) = 20 \cdot {\rm lg}\,\,(4) = 12.04\,{\rm dB}\hspace{0.05cm}.$$ | :$$a_{\rm K}(f = 0) = 20 \cdot {\rm lg}\,\,(4) = 12.04\,{\rm dB}\hspace{0.05cm}.$$ | ||
− | * | + | *With the given coefficient $\alpha_0 =5.1 \ \rm dB/km$, this gives the line length $l = 12.04/5.1\; \underline{= 2.36 \ \rm km}$. |
− | '''(4)''' | + | '''(4)''' Using the given equations and $l = 2.36 \ \rm km$, we obtain: |
:$$a_{\rm K}(f = 120\,{\rm kHz}) = (5.1 + 14.3 \cdot 0.12^{\hspace{0.05cm}0.59}) \cdot 2.36\,{\rm dB}\hspace{0.15cm}\underline{ \approx 21.7\,{\rm dB}}\hspace{0.05cm},$$ | :$$a_{\rm K}(f = 120\,{\rm kHz}) = (5.1 + 14.3 \cdot 0.12^{\hspace{0.05cm}0.59}) \cdot 2.36\,{\rm dB}\hspace{0.15cm}\underline{ \approx 21.7\,{\rm dB}}\hspace{0.05cm},$$ | ||
:$$b_{\rm K}(f = 120\,{\rm kHz}) = (32.9 \cdot 0.12 + 2.26 \cdot 0.12^{\hspace{0.05cm}0.5}) \cdot 2.36\,{\rm rad}\hspace{0.15cm}\underline{ \approx 11.2\,{\rm rad}}\hspace{0.05cm}.$$ | :$$b_{\rm K}(f = 120\,{\rm kHz}) = (32.9 \cdot 0.12 + 2.26 \cdot 0.12^{\hspace{0.05cm}0.5}) \cdot 2.36\,{\rm rad}\hspace{0.15cm}\underline{ \approx 11.2\,{\rm rad}}\hspace{0.05cm}.$$ |
Revision as of 10:37, 22 November 2021
In $\rm ISDN$ (Integrated Services Digital Networks), the terminal (near the subscriber) is connected to a local exchange (OVSt) by a copper pair, with two pairs twisted into a so-called four-wire line.
- Several such four-wire line pairs are twisted to form a basic bundle,
- several basic bundles are combined to form a main bundle (see diagram).
In the network of Deutschen Telekom (formerly: Deutsche Bundespost), mostly copper lines with $\text{0.4 mm}$ core diameter, are found, for whose attenuation and phase function given in [PW95] are the following equations:
- $${{a}_{\rm K}(f)}/{\rm dB} = \left [ 5.1 + 14.3 \cdot \left ({f}/{\rm MHz}\right )^{0.59}\right ]\cdot{l}/{\rm km} \hspace{0.05cm},$$
- $${b_{\rm K}(f)}/{\rm rad} = \left [ 32.9 \cdot ({f}/{\rm MHz}) + 2.26 \cdot \left ({f}/{\rm MHz}\right )^{0.5}\right ]\cdot {l}/{\rm km} \hspace{0.05cm}.$$
Here $l$ denotes the line length.
Notes:
- The exercise belongs to the chapter Properties of Balanced Copper Pairs.
- For more information on the attenuation behavior of copper lines, see Vierdraht-und Zweidraht-Übertragung page in the book "Examples of Communication Systems".
- You can use the (German language) interactive SWF applet "Dämpfung von Kupferkabeln" ⇒ "Attenuation of copper cables" to check your results.
- [PW95] denotes the following literature reference: Pollakowski, P.; Wellhausen, H.-W.: Eigenschaften symmetrischer Ortsanschlusskabel im Frequenzbereich bis 30 MHz. Deutsche Telekom AG, Forschungs- und Technologiezentrum Darmstadt, 1995.
Questions
Solution
(1) Two-wire transmission is used in the connection area. The possible connections are therefore equal to the number of pairs in the main cable:
- $$N = 5 \cdot 5 \cdot 2 \hspace{0.15cm}\underline{= 50}.$$
(2) Solutions 1 and 2 are correct:
- In two-wire transmission, a direction separation method is required, namely the so-called hybrid coil. This has the task that at receiver $\rm A$ only the transmitted signal of subscriber $\rm B$ arrives, but not the own transmitted signal. This is generally quite successful with narrow–band signals – for example speech – but not completely ⇒ solution 1 is correct.
- Solution 2 is also correct. Due to inductive and capacitive couplings, crosstalk can occur from the twin wire located in the same four-wire line, whereby near-end crosstalk (i.e. the interfering transmitter and the interfered receiver are located together) leads to greater impairments than far-end crosstalk.
- On the other hand, the last solution is not applicable. Pulse interference ⇒ the mutual interfering influence of neighboring symbols can certainly occur, but it is not related to two-wire transmission. The reason for such pulse interference is rather linear distortion, caused by a non-ideal attenuation or phase response.
(3) The DC attenuation by a factor of $4$ can be expressed as follows:
- $$a_{\rm K}(f = 0) = 20 \cdot {\rm lg}\,\,(4) = 12.04\,{\rm dB}\hspace{0.05cm}.$$
- With the given coefficient $\alpha_0 =5.1 \ \rm dB/km$, this gives the line length $l = 12.04/5.1\; \underline{= 2.36 \ \rm km}$.
(4) Using the given equations and $l = 2.36 \ \rm km$, we obtain:
- $$a_{\rm K}(f = 120\,{\rm kHz}) = (5.1 + 14.3 \cdot 0.12^{\hspace{0.05cm}0.59}) \cdot 2.36\,{\rm dB}\hspace{0.15cm}\underline{ \approx 21.7\,{\rm dB}}\hspace{0.05cm},$$
- $$b_{\rm K}(f = 120\,{\rm kHz}) = (32.9 \cdot 0.12 + 2.26 \cdot 0.12^{\hspace{0.05cm}0.5}) \cdot 2.36\,{\rm rad}\hspace{0.15cm}\underline{ \approx 11.2\,{\rm rad}}\hspace{0.05cm}.$$