Joint description of amplitude and angle modulation


Joint description of amplitude and angle modulation

In the following two chapters  Amplitude Modulation  (AM) and  Angle Modulation  (WM – from German "Winkelmodulation", including PM as well as FM) we will always consider the set-up shown in the image on the right.  Here, the central block is the  Modulator.

The two input signals and the output signal have the following characteristics::

  • The  source signal  $q(t)$  is the low frequency message signal and has the spectrum  $Q(f)$.  This signal is continuous in value and time and limited to the frequency range  $|f| ≤ B_{\rm NF}$ (NF from German "Niederfrequenz" i.e. low frequency).
    • The  carrier signal  $z(t)$  is a harmonic oscillation of the form
$$z(t) = A_{\rm T} \cdot \cos(2 \pi f_{\rm T} t - \varphi_{\rm T})= A_{\rm T} \cdot \cos(2 \pi f_{\rm T} t + \phi_{\rm T})\hspace{0.05cm}.$$
  • The  transmission signal  $s(t)$  is a higher frequency signal, whose spectral function  $S(f)$ is in the range around the carrier frequency $f_{\rm T}$ .


The modulator output signal  $s(t)$  depends on both input signals  $q(t)$  and  $z(t)$ .  The modulation methods considered below differ only by different combinations of  $q(t)$  and  $z(t)$.

$\text{Definition:}$  Each  Harmonic Oscillation  $z(t)$  can be described by

  • the amplitude  $A_{\rm T}$,
  • the frequency  $f_{\rm T}$  and
  • the zero phase position  ${\it ϕ}_{\rm T}$ .


Though the above left equation with a minus sign and  $φ_{\rm T}$  is mostly used for the application of Fourier series and Fourier integrals, the right equation with  ${\it ϕ}_{\rm T} = \ – φ_{\rm T}$  and a plus sign is more common for the description of modulation processes.


Eine sehr einfache, leider nicht immer ganz richtige Modulatorgleichung


$\text{Definition:}$  Ausgehend von der harmonischen Schwingung  (hier mit der Kreisfrequenz  $ω_{\rm T} = 2πf_{\rm T}$  geschrieben)

$$z(t) = A_{\rm T} \cdot \cos(\omega_{\rm T}\cdot t + \phi_{\rm T})$$

kommt man zur  allgemeinen Modulatorgleichung, indem die bisher festen Schwingungsparameter als zeitabhängig angesetzt werden:

$$s(t) = a(t) \cdot \cos \big[\omega(t) \cdot t + \phi(t)\big ]\hspace{0.05cm}.$$

$\text{!! Vorsicht !!}$  Diese allgemeine Modulatorgleichung ist sehr einfach und plakativ und trägt zum Verständnis der Modulationsverfahren bei.  Leider stimmt diese Gleichung bei der Frequenzmodulation nur in Ausnahmefällen.  Hierauf wird im Kapitel  Signalverläufe bei Frequenzmodulation  noch ausführlich eingegangen.


Als Sonderfälle sind in dieser Gleichung enthalten:

  • Bei der  Amplitudenmodulation  $\rm (AM)$  ändert sich die zeitabhängige Amplitude  $a(t)$  entsprechend dem Quellensignal  $q(t)$, während die beiden anderen Signalparameter konstant sind:
$$\omega(t) = \omega_{\rm T} = {\rm const.}\hspace{0.08cm}, \hspace{0.2cm}\phi(t) = \phi_{\rm T} = {\rm const.}\hspace{0.08cm}, \hspace{0.2cm} a(t) = {\rm Funktion \hspace{0.15cm}von}\hspace{0.15cm}q(t) .$$
  • Bei der Frequenzmodulation  $\rm (FM)$  wird ausschließlich die momentane (Kreis–)Frequenz  $\omega(t)$  durch das Quellensignal  $q(t)$  bestimmt:
$$a(t) = A_{\rm T} = {\rm const.}\hspace{0.08cm}, \hspace{0.2cm}\phi(t) = \phi_{\rm T} = {\rm const.}\hspace{0.08cm}, \hspace{0.2cm} \omega(t)= {\rm Funktion \hspace{0.15cm}von}\hspace{0.15cm}q(t) .$$
  • Bei der Phasenmodulation  $\rm (PM)$  variiert die Phase  $\phi(t)$  entsprechend dem Quellensignal  $q(t)$:
$$a(t) = A_{\rm T} = {\rm const.}\hspace{0.08cm}, \hspace{0.2cm}\omega(t) = \omega_{\rm T} = {\rm const.}\hspace{0.08cm}, \hspace{0.2cm} \phi(t) = {\rm Funktion \hspace{0.15cm}von}\hspace{0.15cm}q(t) .$$


Bei diesen grundlegenden Verfahren werden also stets zwei der drei Schwingungsparameter konstant gehalten.

  • Daneben gibt es auch Varianten mit mehr als einer Zeitabhängigkeit von Amplitude, Frequenz bzw. Phase.
  • Ein Beispiel hierfür ist die  Einseitenbandmodulation, bei der sowohl  $a(t)$  als auch  ${\it ϕ}(t)$  vom Quellensignal  $q(t)$  beeinflusst werden.


Modulierte Signale bei digitalem Quellensignal


Bei der Beschreibung von  $\rm AM$,  $\rm FM$  und  $\rm PM$  wird meist das Quellensignal  $q(t)$  als zeit- und wertkontinuierlich angenommen.

  • Die obigen Gleichungen lassen sich aber auch auf ein rechteckförmiges Quellensignal anwenden.
  • $q(t)$  ist in diesem Fall zeitkontinuierlich, aber wertdiskret.  Damit sind auch  Lineare digitale Modulationsverfahren  beschreibbar.


$\text{Beispiel 1:}$  Die Grafik zeigt oben ein rechteckförmiges Quellensignal  $q(t)$    ⇒   Basisbandsignal, und darunter gezeichnet die modulierten Signale  $s(t)$, die sich bei wichtigen digitalen Modulationsverfahren ergeben.

Basisbandsignal sowie  $\rm ASK$,  $\rm FSK$  und  $\rm PSK$
  • Bei der Amplitudenmodulation, deren digitale Variante unter der Bezeichnung Amplitude Shift Keying  $\rm (ASK)$  bekannt ist, ist das Nachrichtensignal in der Hüllkurve von  $s(t)$  zu erkennen.


  • Im Signalverlauf der Frequency Shift Keying  $\rm (FSK)$  werden die beiden möglichen Signalwerte von  $q(t) = +1$   bzw.   $q(t) =-1$  durch zwei unterschiedliche Frequenzen dargestellt.


  • Phase Shift Keying  $\rm (PSK)$  führt bei Amplitudensprüngen des Quellensignals  $q(t)$  zu Phasensprüngen im Signal  $s(t)$, im binären Fall jeweils um  $\pm π$  (bzw. $\pm 180^\circ$).

Beschreibung des physikalischen Signals mit Hilfe des analytischen Signals


Das modulierte Signal  $s(t)$  ist bandpassartig.  Wie bereits im Buch „Signaldarstellung” beschrieben wurde, wird ein solches BP–Signal  $s(t)$  häufig durch das dazugehörige  analytische Signal  $s_+(t)$  charakterisiert. Zu beachten ist:

  • Das analytische Signal  $s_+(t)$  erhält man aus dem reellen, physikalischen Signal  $s(t)$, indem zu diesem als Imaginärteil dessen Hilberttransformierte hinzugefügt wird:
$$s_+(t) = s(t) + {\rm j} \cdot {\rm H}\{ s(t)\}\hspace{0.05cm}.$$
  • Das analytische Signal  $s_+(t)$  ist somit stets komplex.  Zwischen den beiden Zeitsignalen gilt der folgende einfache Zusammenhang:
$$s(t) = {\rm Re} \big[s_+(t)\big] \hspace{0.05cm}.$$
  • Das Spektrum  $S_+(f)$  des analytischen Signals ergibt sich aus dem zweiseitigen Spektrum  $S(f)$, wenn man dieses bei positiven Frequenzen verdoppelt und für negative Frequenzen zu Null setzt:
$$S_+(f) =\big[ 1 + {\rm sign}(f)\big] \cdot S(f) = \left\{ \begin{array}{c} 2 \cdot S(f) \\ 0 \\ \end{array} \right.\quad \begin{array}{*{10}c} {\rm{f\ddot{u}r}} \\ {\rm{f\ddot{u}r}} \\ \end{array}\begin{array}{*{20}c} f>0 \hspace{0.05cm}, \\ f<0 \hspace{0.05cm}, \\ \end{array} \hspace{1.3cm} \text{mit}\hspace{1.3cm} {\rm sign}(f) = \left\{ \begin{array}{c} +1 \\ -1 \\ \end{array} \right.\quad \begin{array}{*{10}c} {\rm{f\ddot{u}r}} \\ {\rm{f\ddot{u}r}} \\ \end{array}\begin{array}{*{20}c} f>0 \hspace{0.05cm}, \\ f<0 \hspace{0.05cm}. \\ \end{array}$$


Verdeutlichung des analytischen Signals im Frequenzbereich

$\text{Beispiel 2:}$  Die obere Grafik zeigt das Spektrum  $S(f)$  eines reellen Zeitsignals  $s(t)$.  Man erkennt:

  • Die Achsensymmetrie der Spektralfunktion  $S(f)$  bezüglich der Frequenz  $f=0$:  
$${\rm Re}\big[S( - f)\big] = {\rm Re}\big[S(f)\big].$$
  • Hätte das Spektrum des reellen Zeitsignals  $s(t)$  einen Imaginärteil, so wäre dieser punktsymmetrisch um  $f=0$:
$${\rm Im}\big[S( - f)\big] = - {\rm Im}\big[S(f)\big].$$


Unten ist das Spektrum  $S_+(f)$  des zugehörigen analytischen Signals  $s_+(t)$  dargestellt.  Dieses ergibt sich aus  $S(f)$  durch

  • Abschneiden der negativen Frequenzanteile:   $S_+(f) \equiv 0$  für  $f<0$,
  • Verdoppeln der positiven Frequenzanteile:   $S_+(f ) = 2 \cdot S(f )$  für  $f \ge 0$.


Bis auf einen nicht praxisrelevanten Sonderfall ist das analytische Signal  $s_+(t)$  stets komplex.


Wir wenden nun diese Definitionen auf das modulierte Signal  $s(t)$  an. Im Sonderfall  $q(t) \equiv 0$  ist  $s(t)$  wie das Trägersignal  $z(t)$  eine harmonische Schwingung.  Es gilt:

$$s(t) = A_{\rm T} \cdot \cos(\omega_{\rm T}\cdot t + \phi_{\rm T}) \hspace{0.3cm} \Leftrightarrow \hspace{0.3cm} s_+(t) = A_{\rm T} \cdot {\rm e}^{\hspace{0.03cm}{\rm j} \hspace{0.03cm}(\omega_{\rm T}\hspace{0.05cm} t \hspace{0.05cm} + \phi_{\rm T})}\hspace{0.05cm}.$$

Die zweite Gleichung beschreibt einen Drehzeiger mit folgenden Eigenschaften:

  • Die Zeigerlänge kennzeichnet die Signalamplitude  $A_{\rm T}$.
  • Zur Zeit  $t = 0$  liegt der Zeiger mit dem Winkel  $ϕ_{\rm T}$  in der komplexen Ebene.
  • Für  $t > 0$  dreht der Zeiger mit konstanter Winkelgeschwindigkeit  $ω_{\rm T}$  in mathematisch positive Richtung (entgegen dem Uhrzeigersinn).
  • Die Zeigerspitze liegt stets auf einem Kreis mit dem Radius  $A_{\rm T}$  und benötigt für eine Umdrehung genau die Periodendauer  $T_0$.


Verdeutlichung des analytischen Signals im Zeitbereich für  $ϕ_{\rm T} = -45^\circ$



Um den Zusammenhang  $s(t) = {\rm Re}[s_+(t)]$  im Querformat zeigen zu können, ist die komplexe Ebene entgegen der üblichen Darstellung um  $90^\circ$  nach links gedreht:  

        Der Realteil ist nach oben und der Imaginärteil nach links aufgetragen.
Die einzelnen Modulationsverfahren lassen sich nun wie folgt darstellen:

  • Bei der  Amplitudenmodulation  ändert sich die Zeigerlänge  $a(t) = |s_+(t)|$  und damit die Hüllkurve von  $s(t)$  entsprechend dem Quellensignal  $q(t)$.
    Die Winkelgeschwindigkeit  $ω(t)$  ist dabei konstant.
  • Bei der  Frequenzmodulation  ändert sich die Winkelgeschwindigkeit  $ω(t)$  des rotierenden Zeigers entsprechend  $q(t)$,
    während die Zeigerlänge  $a(t) = A_{\rm T}$  nicht verändert wird.
  • Bei der  Phasenmodulation  ist die Phase  $ϕ(t)$  zeitabhängig.
    Es bestehen viele Gemeinsamkeiten mit der Frequenzmodulation, die ebenfalls zur Klasse der Winkelmodulation zählt.


Beschreibung des physikalischen Signals mit Hilfe des äquivalenten TP-Signals


Manche Sachverhalte bezüglich der sendeseitigen Modulation und der Demodulation am Empfänger lassen sich anhand des  äquivalenten Tiefpass–Signals  entsprechend der Definition im Buch „Signaldarstellung” anschaulich am besten erklären.

Für dieses Signal  $s_{\rm TP}(t)$  und dessen Spektrum  $S_{\rm TP}(f)$  gelten die folgenden Aussagen:

Zum äquivalenten Tiefpass–Signal im Frequenzbereich
  • Das Spektrum  $S_{\rm TP}(f)$  des äquivalenten Tiefpass–Signals erhält man aus  $S_+(f)$  durch Verschiebung um  $f_{\rm T}$  nach links und liegt somit im Bereich um die Frequenz  $f =0$:
$$S_{\rm TP}(f) = S_+(f + f_{\rm T}) \hspace{0.05cm}.$$
$$s_{\rm TP}(t) = s_+(t) \cdot {\rm e}^{{-\rm j}\hspace{0.08cm} \omega_{\rm T} \hspace{0.03cm}t }\hspace{0.05cm}.$$
  • Das äquivalente Tiefpass–Signal einer unmodulierten harmonischen Schwingung ist für alle Zeiten konstant   –   die Ortskurve besteht in diesem Sonderfall aus einem einzigen Punkt:
$$s(t) = A_{\rm T} \cdot \cos(\omega_{\rm T}\cdot t + \phi_{\rm T}) \hspace{0.3cm} \Leftrightarrow \hspace{0.3cm} s_+(t) = {\rm e}^{\hspace{0.03cm}{\rm j} \hspace{0.03cm}(\omega_{\rm T}\hspace{0.05cm} t \hspace{0.05cm} + \phi_{\rm T})}\hspace{0.05cm},$$
$$ s_+(t) = {\rm e}^{\hspace{0.03cm}{\rm j} \hspace{0.03cm}(\omega_{\rm T}\hspace{0.05cm} t \hspace{0.05cm} + \phi_{\rm T})}\hspace{0.3cm} \Leftrightarrow \hspace{0.3cm} s_{\rm TP}(t) = A_{\rm T} \cdot {\rm e}^{\hspace{0.03cm}{\rm j} \hspace{0.03cm} \cdot \hspace{0.05cm} \phi_{\rm T}}\hspace{0.05cm}.$$


$\text{Wichtiges Ergebnis:}$  Für ein amplituden– oder phasenmoduliertes Signal mit der Trägerfrequenz  $f_{\rm T}$  gilt dagegen:

$$s(t) = a(t) \cdot \cos(\omega_{\rm T}\cdot t + \phi(t)) \hspace{0.3cm} \Leftrightarrow \hspace{0.3cm} s_{\rm TP}(t) = a(t) \cdot {\rm e}^{\hspace{0.03cm}{\rm j} \hspace{0.03cm} \cdot \hspace{0.05cm} \phi (t)}\hspace{0.05cm}.$$

Die Hüllkurve  $a(t)$  und der Phasenverlauf  $ϕ(t)$  des (physikalischen) Bandpass-Signals  $s(t)$  bleiben auch im äquivalenten TP–Signal  $s_{\rm TP}(t)$  erhalten.


$\text{Beispiel 3:}$  Die Grafik zeigt jeweils rechts das modulierte Signal  $s(t)$   ⇒   roter Signalverlauf im Vergleich zum Trägersignal  $z(t)$   ⇒   blauer Signalverlauf.
Links dargestellt sind die jeweiligen äquivalenten Tiefpass–Signale  $s_{\rm TP}(t)$   ⇒   grüne Ortskurven.

Sendesignale bei Amplituden– und Winkelmodulation

Oben ist die  Amplitudenmodulation  beschrieben, bei der das Quellensignal  $q(t)$  in der Hüllkurve  $a(t)$  zu erkennen ist:

  • Da die Nulldurchgänge des Trägers  $z(t)$  erhalten bleiben, ist  $ϕ(t) = 0$  und das äquivalente TP–Signal  $s_{\rm TP}(t) = a(t)$  reell.


Unten ist die  Winkelmodulation  verdeutlicht.

  • Hier ist die Hüllkurve  $a(t)$  konstant   ⇒   das äquivalente TP-Signal  $s_{\rm TP}(t) = A_{\rm T} · e^{\rm j·ϕ(t)}$  beschreibt einen Kreisbogen.
  • Die Information über das Nachrichtensignal  $q(t)$  steckt hier in der Lage der Nulldurchgänge von  $s(t)$.
  • Genaueres hierüber finden Sie im Kapitel Gemeinsamkeiten zwischen PM und FM


Hinweise:

  • Wir bezeichnen im Folgenden den zeitabhängigen Verlauf von  $s_{\rm TP}(t)$  in der komplexen Ebene auch als "Ortskurve", während das "Zeigerdiagramm" den Verlauf des analytischen Signals  $s_+(t)$  beschreibt.
  • Der hier dargelegte Sachverhalt wird mit zwei interaktiven Applets im Zeitbereich verdeutlicht:
(1)  Physikalisches Signal & Analytisches Signal ,
(2)  Physikalisches Signal & Äquivalentes TP-Signal.


Aufgaben zum Kapitel


Aufgabe 1.4: Zeigerdiagramm und Ortskurve

Aufgabe 1.4Z: Darstellungsformen von Schwingungen